Live · Available now

DICOM Imaging. DICOM anonymisation
that lives inside
your network.

ScanIQ™ processes DICOM identity - header tags, private creator tags and burnt-in pixel overlays - before any study leaves your PACS. On-prem. Inline. PS3.15 aligned.

113
DICOM PS3.15 Annex E attributes
Inline
Per study
PS3.15
Aligned
The governance model

ScanIQ™ applies the SECUVA governance model to Medical Imaging.Patient identity never leaves your network.

Control

Controlling what approved AI relationships may receive.

Minimise

Removing patient identity inside the customer environment when the approved purpose does not require it.

Evidence

Preserving evidence of what was released.

The problem

DICOM carries patient identity in three places.Most tools miss two of them.

A standard CT study can expose a patient across header tags, pixel overlays, and structured report fields simultaneously. Header-only de-identification - which is what most PACS export scripts do - leaves two surfaces untouched.

Surface 01

DICOM header fields

Comprehensive PS3.15-aligned attribute coverage - patient names, dates of birth, accession numbers, institution names, referring physicians and more.

Header scrub · configurable per-tag profile

Surface 02

Modality-aware identity controls

Release rules account for the modality of every study. Studies that need extra identity handling are held back rather than released.

Surface 03

Structured reports & PR objects

SR, KO, and GSPS objects carry referenced UIDs, text values, and coded sequences that survive header stripping.

Full SR parse · coded sequence scrub

How it works

The ScanIQ™ pipeline.

Every step runs inside your network. Nothing raw ever leaves.

  1. 01

    PACS Intercept

    Study arrives via standard DICOM transport. Minimal network configuration.

  2. 02

    Modality check

    Studies from modalities that need extra identity handling are held back rather than released.

  3. 03

    Header Scrub

    PS3.15-aligned attribute coverage. Structured reports, key objects and presentation states parsed and cleaned.

  4. 04

    Policy Check

    Release rules validated. Recipient allowlist enforced. DUA compliance verified.

  5. 05

    Governed Output

    Clean study forwarded. Immutable ledger entry written.

Integration

Transparent proxy.Your PACS never knows it is there.

ScanIQ deploys as an on-prem agent inside your network. No changes to your PACS configuration. No radiologist workflow disruption.

DeploymentOn-prem agent · flexible deployment
HA / DRHigh-availability · automated failover
MonitoringReal-time metrics dashboard
Tested PACS / VNA compatibility
Sectra IDS7
Intelerad
Fujifilm Synapse
Agfa Enterprise
Philips Vue PACS
Change Healthcare
RamSoft PowerServer
GE Centricity
Merge / IBM iConnect
DICOM-conformant VNA

Any DICOM-compliant PACS supported via standard transport. Custom connector available on request.

Capabilities

What ScanIQ™ covers.

Modality-aware identity controls

Release rules account for the modality of every study. Studies that need extra identity handling are held back rather than released, so a study is never released on an assumption.

SOP classes covered
CTMRDXMGSCSRXANMCRUS

PS3.15 header scrub

PS3.15-aligned attribute coverage. Configurable retain / remove / pseudonymise per attribute, per destination.

SR & KO handling

Structured Reports, Key Objects, and Presentation States processed natively - not skipped as most tools do.

Policy-gated release

Each destination receives only what its data-use agreement permits, and an unregistered destination receives nothing.

Immutable audit ledger

Every anonymisation decision recorded in an independently verifiable ledger - exportable for institutional ethics review (IRB / REC / REB / HREC) and privacy or AI regulator audit.

Use cases

When teams reach for ScanIQ™.

Sending studies to an AI vendor

Your AI vendor needs de-identified DICOM. ScanIQ intercepts studies leaving your PACS, strips PHI on-prem, and forwards clean images - no manual export, no compliance gap.

Building a research cohort

Ethics approval covers de-identified images. ScanIQ processes your retrospective archive and releases anonymised studies to a research PACS or S3 bucket - with an immutable audit trail for your HREC.

Multi-site clinical trials

Standardise de-identification across sites. ScanIQ applies the same PS3.15 profile everywhere, maintains consistent pseudonymous UIDs across the trial, and logs every transfer centrally.

Training an internal AI model

Your data science team needs labelled DICOM. ScanIQ de-identifies and releases to your internal GPU cluster - PHI never touches a research environment, governance is automatic.

Technical specifications

Built for PACS integration, not alongside it.

ScanIQ runs as a transparent DICOM proxy. Your PACS does not know it is there. No workflow changes for radiologists. No integration project for IT.

Protocol support
Standard DICOM transport · DICOMweb compatible
DICOM profile
PS3.15-aligned · configurable confidentiality profiles
Modalities
CT · MR · DX · MG · CR · XA · NM · PT · US · SC and all secondary capture
Throughput
Inline per-study · bulk mode
Deployment
On-prem agent · no cloud data path for raw studies
Audit format
Immutable audit format · exportable for HREC review
Standards
DICOM PS3.15 (Annex E Basic Application Level Confidentiality Profile) · HIPAA § 164.514 De-identification · GDPR Art. 25/32 & EDPB Pseudonymisation · Privacy Act / OAIC APP 11 · PIPEDA / PHIPA · ISO/IEC 27001-aligned
Live · Available now

See ScanIQ™ on your DICOM infrastructure.

We will connect to your PACS in a sandbox and run a live anonymisation demo against your study format.